Basic Operation Details Of Series Of Sany X Type Outrigger Concrete Pump Truck Proximity Control Out

Outrigger operation precautions:1. The outriggers must be kept at a safe distance from pits, slopes, ditches, excavations and other machines.
2. Minimum distance A from the slope: (see the figure below)
a. Outrigger pressure≤ 12t, A=1m;

Outrigger operation precautions:

1. The outriggers must be kept at a safe distance from pits, slopes, ditches, excavations and other machines.

2. Minimum distance A from the slope: (see the figure below)

a. Outrigger pressure≤ 12t, A=1m;

b.Outrigger pressure> 12t, A=2m;

1

3. Regardless of the ground conditions, the supporting ground must be level, and a horizontal supporting surface must be made if necessary, and it cannot be supported on a cavity.

2

4. When the ground sinks severely, the boom must be folded up immediately and the outriggers must be re-padded before operation.

5. The width indicator lights must be turned on during construction at night( turning on the chassis headlights, and the width indicator lights will be turned on).

3

6. The boom must be fully folded and the boom in-position travel switch must be pressed down before the outriggers can move.

4

Proximity control outrigger deployment operation:

1. Once the Sany X-type outrigger  concrete pump truck  position is successfully switched,switch the” near/ remote control” button on the outrigger operation box to the near control state.

5

2. Check whether there is an”Emergency Stop”alarm signal on the display screen, if there is, then all the emergency stop switches must be reset, a total of 4.( ①②On the outrigger control valves on both sides, ③On the rear outrigger operation box, ④On the main function operation box under the boom support).

6

3. Clear any obstacles within the outrigger movement range and open all outrigger safety locks.

7

8

Share your love

Leave a Reply

Your email address will not be published. Required fields are marked *