Emergency Treatment For Concrete Pump Trucks Failures Part 12

Concrete pump truck malfunction:Double gear  pump truck, low pressure in the reversing system, no force in the swing of the S pipe.
Phenomenon and reasons:The directional pressure is too low, and at this time, the directional pressu...

Concrete pump truck malfunction:

Double gear  pump truck, low pressure in the reversing system, no force in the swing of the S pipe.

Phenomenon and reasons:

The directional pressure is too low, and at this time, the directional pressure will swing below 14Mpa, causing the S pipe to swing weakly and making concrete pumping difficult.

1. Main overflow leakage or damage;

1

2. Internal leakage or damage of gear pump.

2

3. The pressure of the accumulator airbag is insufficient or leaking.

3

Emergency elimination methods:

1. Swap the mixing overflow valve with the reversing overflow valve;

2. Swap the two outlet pressure oil pipes of the dual gear pump;

3. Place a nitrogen cylinder on the vehicle, inflate it, and replace the airbag after pumping the concrete.

Service is endless, focusing on high quality  used construction machinery, and professionally serving global customers, Mecha Brothers looks forward to cooperating with you and make a win-win development with you.